Price 30000 INR/ Piece

MOQ : 100 Pieces

PPS Chlorine Sensor Specification

  • Resistance
  • 100
  • Output
  • Analog Voltage Output
  • Theory
  • Chlorine Gas Electrochemical Principle
  • Type
  • Electrochemical Sensor
  • Accuracy
  • 2% F.S.
  • Operating Voltage
  • 5V DC
  • Output Voltage
  • 0.4V - 2V
  • Compensated Temperature
  • 0C to 50C
  • Storage Temperature
  • -20C to 60C
  • Operating Temperature
  • -20C to 50C
  • Humidity Range
  • 15% to 90% RH (non-condensing)
  • Pressure Range
  • Standard Atmospheric Pressure
  • Expected Lifetime
  • 2 years (in air)
  • Weight
  • Approx. 8g
  • Sensor Pin Configuration
  • 3-pin
  • Recovery Time
  • 60 seconds
  • Dimension
  • 20mm (Dia) 16.5mm (Height)
  • Housing Material
  • PPS Plastic
  • Response Time
  • 30 seconds
  • Measuring Range
  • 0-20 ppm (parts per million)
 

PPS Chlorine Sensor Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Payment Terms
  • Cash Advance (CA)
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About PPS Chlorine Sensor

PPS Chlorine Sensor that our well-distinguished enterprise puts forward is engineered to be utilized for the measurement the amount of chlorine in a solution. Ideal for diverse industrial applications, this type of sensor can be utilized for process water, drinking water, and industrial water treatment. The proposed sensor comes with long cord to put deeply it into the water to measure accurate amount of chlorine. Easy to use, highly efficient, and low maintenance, clients can get PPS Chlorine Sensor at market justified prices.


Fast and Reliable Chlorine Detection

Engineered for efficiency, the PPS Chlorine Sensor delivers rapid chlorine gas measurements with a response time under 30 seconds. Its electrochemical sensing principle ensures consistently precise output, making it a trusted choice for critical industrial monitoring. Designed for harsh atmospheric conditions, the sensor maintains accuracy across varying temperature and humidity levels.


Durable Construction and Practical Design

Built using high-grade PPS plastic and steel, the sensor is both lightweight (approx. 8g) and robust, capable of withstanding challenging industrial environments. Its compact dimensions allow for easy integration and maintenance, while the three-pin configuration ensures straightforward installation and stable connectivity.


Versatile Industrial Applications

This sensor is tailored for diverse industrial contexts, offering reliable chlorine detection for process control, safety monitoring, and environmental compliance. Its compatibility with standard LCD resolution outputs and analog voltage range provides flexibility for integration with a range of monitoring systems and control panels.

FAQ's of PPS Chlorine Sensor:


Q: How does the PPS Chlorine Sensor detect chlorine gas?

A: The sensor uses an electrochemical principle to detect chlorine concentration. When chlorine gas comes into contact with the sensor, a chemical reaction produces an electrical signal, which is then converted to an analog voltage output (0.4V to 2V) for measurement.

Q: What benefits does the PPS Chlorine Sensor provide for industrial applications?

A: This sensor offers fast response times, high accuracy (2% F.S.), and a long expected service life of two years. Its broad operating range makes it ideal for continuous monitoring in demanding industrial environments, enhancing safety and regulatory compliance.

Q: When should I calibrate or replace the sensor?

A: Calibration intervals depend on usage and environment, but periodic calibration is recommended for optimum accuracy. The sensor features an expected lifetime of two years in air, after which replacement is advised for continued performance.

Q: Where can the PPS Chlorine Sensor be installed?

A: It can be integrated into various industrial systems that require chlorine monitoring, such as gas detection panels, safety alarms, and process controls. The sensor's compact design facilitates installation in space-constrained environments.

Q: What is the operating process for this chlorine sensor?

A: Once connected to a power source (5V DC), the sensor continuously monitors chlorine levels and outputs corresponding analog voltage signals. These can be read by display modules or integrated into existing control and monitoring systems.

Q: How should the sensor be stored and handled before installation?

A: Store the sensor in a non-condensing humidity range (15%-90% RH) and within a temperature range of -20C to 60C to maintain its integrity. Handle with care to prevent mechanical or electrical damage prior to use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Water PH Sensor Category

DAX PH Sensor

DAX PH Sensor

Price 30000 INR / Piece

Minimum Order Quantity : 100 Pieces

Operating Temperature : 0C to 60C

Type : Glass Electrode

Accuracy : 0.02 pH

Output : Other, Analog Voltage Signal

RS485 Output Signal Sensor

RS485 Output Signal Sensor

Price 30000 INR / Piece

Minimum Order Quantity : 100 Pieces

Operating Temperature : 20C to +80C

Type : RS485 Output Signal Sensor

Accuracy : 0.5% FS

Output : Other, RS485 Digital Signal

Spectral Sensors with Transmitter

Spectral Sensors with Transmitter

Price 30000 INR / Piece

Minimum Order Quantity : 100 Pieces

Operating Temperature : 20C to +60C

Type : Spectral Sensor with Transmitter

Accuracy : 1%

Output : Other, Analog / Digital (configurable)

Hardness Fluoride Ion Sensor

Hardness Fluoride Ion Sensor

Price 30000 INR / Piece

Minimum Order Quantity : 100 Pieces

Operating Temperature : 0C to 60C

Type : Ion Selective Electrode (ISE) Sensor

Accuracy : 2% F.S.

Output : Other, Analog